ラボジャッキ


  • Three Sizes: Heavy Duty (L490), Mini (L200), & Compact (LJ750)
  • Rectangular Jacks Offer Rugged, Dual Pantograph Design
  • Large Array of Mounting Holes on Each Platform

Application Idea

LJ750

1.00" Vertical Travel,
200 lbs Load Capacity

PM4

(One Included with Each Unit)

L200

1.03" Vertical Travel,
50 lbs Load Capacity

L490

2.26" Vertical Travel,
75 lbs Load Capacity

4"

7"

4"

3"

Ø2.64"

Related Items


Please Wait
Item #Vertical TravelMounting SurfaceMax Load Capactiy
L490(/M) 2.26"
(57.4 mm)
7.00" x 4.00"
(177.8 mm x 101.6 mm)
75 lbs
(34.0 kg)
L200(/M) 1.03"
(26.2 mm)
3.00" x 4"
(76.2 mm x 101.6 mm)
50.0 lbs
(22.7 kg)
LJ750(/M) 1.00"
(25.4 mm)
Ø2.64"
(67.0 mm)
200 lbs
(90.7 kg)

ラボジャッキは、光学部品群の高さ調整が必要な場合に光学部品群を取り付けて高さ調整のできる頑丈なプラットフォームです。当社では、幅広いニーズにお応えできるよう、3種類のモデルをご用意しています。

高耐荷重ラボジャッキL490/M
L490/M は、2重パンタグラフ設計により、優れた剛性と台の水平性を備えています。大型の177.8 mm x 101.6 mmの取付け台は、ステンレススチール軸と接続ロッドによって34 kgまでの荷重を支えながら、57.4 mmの調整範囲で滑らかな垂直調整が可能です。上部および底部の両プレートには、取り付け用に多数並んだM6タップ穴と貫通溝があります。

ミニシリーズ対応ラボジャッキL200/M
L200/M は、上記のL490/Mと同じ丈夫な2重パンタグラフ設計です。小型設計で多数のM3取付け穴があるので、当社のミニシリーズ製品と組み合わせて使用できます。76.2 mm x 101.6 mmの取付けプラットフォームは、22.7 kgまでの荷重を支えながら26.2 mmの調整範囲で滑らかな垂直調整が可能です。上部と底部の両プレートには、取付け用に多数のM3、M4、M6穴があいています(詳細は下の赤いアイコンからDocumentsタブの「Auto CAD」をご覧ください)。

小型ラボジャッキLJ750/M
LJ750/M は小型で使いやすい設計で、25.4 mmの精密な垂直調整が可能です。10 μm単位の目盛が付いた大型アクチュエーターリングは、最大90.7 kgの加重がかかっていても高い精度を提供します。上部の台は360º 連続で回転し、固定も可能です。

L200 SmartPack Packaging
Click to Enlarge

Current L200 Packaging

Smart Pack

  • Reduce Weight of Packaging
  • Increase Usage of Recyclable Materials
  • Improve Packing Integrity
  • Decrease Shipping Costs

Thorlabs' Smart Pack Initiative is aimed at minimizing waste while providing adequate protection for our products. By eliminating any unnecessary packaging, implementing design changes, and utilizing eco-friendly materials, this initiative seeks to reduce the environmental impact of our
product packaging.

The updated L200(/M) packaging consists of recycled cardboard and weighs 13% less than the original packaging. This weight change results in a
more than 6.71 kg reduction in travel-based CO2 emissions per year, based on typical product sales.*

The other products on this page have also transitioned to recycled paper packaging. The new L490(/M) packaging results in a 41% reduction in
weight and more than 107.46 kg reduction in travel-based CO2 emissions per year, while the updated LJ750(/M) packaging results in a 28%
reduction in weight and more than 5.15 kg reduction in CO2 emissions per year.* 

As we move through our product line, we will indicate re-engineered, eco-friendly packaging with our Smart Pack logo, which can be seen in the
image to the right.

*This product transitioned to smart packaging in 2013. Travel-based emissions reduction calculations are estimated based on the total weight reduction of packaging materials used for all of that year's product sales, traveling 1,000 miles on an airplane, to provide general understanding of
the impact of packaging material reduction. Calculations were made using the EPA’s shipping emissions values for different modes of transport.


Posted Comments:
user  (posted 2019-12-17 06:44:48.927)
The drawing for LJ750/M shows the top plate as having metric tapped holes with Imperial spacings - is that correct? e.g M6 holes with 1 inch spacing.
YLohia  (posted 2019-12-17 11:38:25.0)
Thank you for contacting Thorlabs. Yes, the LJ750/M has metric holes that have imperial spacings.
user  (posted 2019-11-14 10:28:36.273)
Hello, what is the maximum load if you use the L200 upside down ? That is, if the load pulls the two plates apart, instead of pushing them together.
llamb  (posted 2019-11-18 02:04:59.0)
Thank you for contacting Thorlabs. We have not formally tested the L200 for the inverted orientation, however, we would not expect failure of the unit when using the same load capacity. The key issues in this orientation would be repeatability and stability. When mounted upright on a table, the leadscrew and springs provide a mechanical advantage for a load compressing the two plates together. I have reached out to you directly to discuss your application and this lab jack further.
user  (posted 2019-05-08 09:11:49.407)
Hi! You claim the Ø2.64" Compact Lab Jack(LJ750/M) has a "high stability" - what exactly do you mean with that? The load capacity or positional stability? Do you have any numbers concerning the mechanical creep/long term positional stability of this stage? I'm interested in moderate loads of about 5-10kg, over several hours/days. We are looking for a vertical stage that can keep it's position in the (sub)micron range. Other suggestions are welcome, too!
llamb  (posted 2019-05-10 05:30:58.0)
Thank you for your feedback. The high stability refers to being able to support a high load while maintaining its 10 µm resolution from the engraved dial. We have not tested the long-term positional stability of this stage, as it will also depend on thermal conditions and how the load is mounted. I have reached out to you directly to discuss your application further.
xrb09126  (posted 2017-06-29 11:30:29.127)
For the L200/M labjack we are having problems with what it seems to be the adjuster rod where iis struggling to move the jack at all? Just wondering if you can help
tfrisch  (posted 2017-07-01 11:45:32.0)
Hello, thank you for contacting Thorlabs. I will reach out to you directly to troubleshoot your labjack.
dw  (posted 2017-03-22 16:59:11.467)
After some use, these lab jacks tend to get jammed. It would be very helpful to have some info as to how to take apart the lab jack and fix this.
jlow  (posted 2017-03-29 04:41:06.0)
Response from Jeremy at Thorlabs: Typically the common cause for the stage getting jammed is dirt contamination on the lead screw. If you move the stage until it is at the end of the upright position, you can access the leadscrew somewhat to clean it with solvents (e.g. isopropyl alcohol). Once the lead screw is clean, you can then regrease it. The grease we use on the lead screw is Apiezon M. Afterwards, run the lead screw back and forth fully a few times.
andrew  (posted 2013-07-23 06:32:01.503)
We own a L490/M. Can we add the motorized stage to it? L490MZ/M Motorized Lab Jack, 50.8 mm Travel, M6 Taps http://www.thorlabs.hk/newgrouppage9.cfm?objectgroup_id=4018
cdaly  (posted 2013-07-25 10:34:00.0)
Response from Chris at Thorlabs: Thank you for using our feedback tool. I'm afraid I am not sure if you are asking these can be mounted together or if the manual stage can be turned into a motorized one, so I will answer both. No, unfortunately, the L490(/M) cannot be motorized by adding the controller afterwards. Yes, you would be able to mount one on top of the other. In a perpendicular or offset configuration, you can just use M6 (1/4-20) cap screws, but if you are mounting them together flush to one another, you would need also to use the corresponding nuts in order to fasten them.
rlang  (posted 2012-11-30 00:00:00.0)
The L490/M includes 19 M6 mounting holes manufactured with 25 mm spacing. The tapped holes each include a positional tolerance that would allow the spacing to range between 24.87 mm to 25.13 mm. Our apologies, but our supporting documentation is currently inaccurate and will be updated shortly. Thank you for pointing out this inconsistency, and please note that the L490/M will suit your application.
oleg.mavr  (posted 2012-11-28 11:17:17.123)
This product would be very useful to our company if it is really "METRIC" as it is mentioned in short description of L490/M: "The top and bottom plates each have an array of nineteen 1/4"-20 (M6) tapped mounting holes on 1" (25 mm) centers." However one can see 25.4 mm spacing between tapped mounting holes. Please clarify is it possible to order L490/M with 25.0 mm spacing?
tcohen  (posted 2012-05-14 09:34:00.0)
Response from Tim at Thorlabs: Thank you for contacting us. The L490 uses anodized aluminum and stainless steel almost exclusively. There are, however, a few steel components which may not be stainless. I am checking into this and will contact you with more details.
johannes.sparrer  (posted 2012-05-10 18:56:07.0)
Is the L490 completely made of stainless materials? I would like to use it in an environment with a high humidity.
eliseo  (posted 2010-06-01 00:04:15.0)
Do you have any experience in making the L200 UHV compatible? Would it be feasible to scrub out the lithium grease and replace with vacuum grease?
jjurado  (posted 2010-06-01 21:41:58.0)
Response from Javier at Thorlabs to eliseo: we currently do not offer a vacuum-compatible version of the L200 labjack. There is not only grease, but other components that would require a redesign of the assembly in order to make the L200 vacuum compatibe (~10^-6 Torr). Alternatively, I would suggest looking at our LNR series stainless steel stages. We could customize its mounting accesories for use in vacuum environments. I will contact you with more details.
apalmentieri  (posted 2010-01-27 10:00:00.0)
A response from Adam at Thorlabs to rick: This is a very interesting application and we would like some more information. I will email you directly to get this information. With respect to the grease, the L490 uses Apiezon grease while the L200 uses white lithium for moving parts and a combination of Apiezon grease with NYE PG-44A grease.
vvv  (posted 2010-01-26 16:47:55.0)
I have an application for the L490 and or L200. The lab jacks would be used in a radioactive hot cell. That only causes problems if some kind of solid bearing material is used. Most lubricants are Ok, if one is used; I need to run it through our system.Your help will be appreciated. rick
apalmentieri  (posted 2010-01-14 14:18:45.0)
A response from Adam at Thorlabs, Inc to Dan: I am sorry about the issue with our step files. We will update the web and send you out an accurate step file.
flickingerd  (posted 2010-01-14 11:44:53.0)
The STEP file thats available for L200 is flawed in a subtle but serious way. The hole spacings on the top and bottom plates are incorrect in one dimension. The holes, as modeled, are on a 1" x 25mm grid!
tyler  (posted 2008-03-06 09:33:44.0)
Response from Tyler at Thorlabs to ghegenbart: Thank you for bringing the missing drawings to our attention. They are now available. We are sorry for any inconvenience this may have caused you.
ghegenbart  (posted 2007-11-16 06:39:34.0)
Drawings for LJ750/M are missing.

ラボジャッキ(取付け面積:177.8 mm x 101.6 mm)

Displacement Graph for L490 Lab Jack
Click to Enlarge
1回転あたりのラボジャッキL490の変位量
  • 脱着可能なアクチュエーターノブ付属
  • 高さ調整範囲:57.4 mm
  • 取付け面積:177.8 mm x 101.6 mm
  • 垂直方向耐荷重:34.0 kg
  • M6のマウント用タップ穴 19 か所
  • 上部、および底部プレートの両方にマウント用のスロット付き

ラボジャッキL490/Mには、優れた剛性を発揮するダブルパンタグラフ機構が採用されています。この調整機構では、送りネジを使用して対向する1対の筋交いの間の角度を調整します。ステンレススチール製の軸と接続ロッドによって、34 kgまでの荷重を支えながらジャッキの範囲全体での滑らかな上下動が可能です。上部プレートと底部プレートには25.0 mm間隔で19個のM6取付けタップ穴があります。また、上部プレートと底部プレートはマウント用のスロットも備えています。

+1 数量 資料 型番 - インチ規格 定価(税抜) 出荷予定日
L490 Support Documentation
L490ラボジャッキ、取付け面積7インチ x 4インチ、高さ調整範囲2.26インチ、耐荷重75 lbs(インチ規格)
¥84,124
3-5 Days
+1 数量 資料 型番 - ミリ規格 定価(税抜) 出荷予定日
L490/M Support Documentation
L490/Mラボジャッキ、取付け面積177.8 mm x 101.6 mm、高さ調整範囲57.4 mm、耐荷重34 kg(ミリ規格)
¥84,124
Today

ミニシリーズ対応ラボジャッキ(取付け面積:76.2 mm x 101.6 mm)

Displacement Graph for L200 Mini Lab Jack
Click to Enlarge
1回転あたりのミニラボジャッキL200の変位量
Tap Diagram for L200 Mini Lab Jack
Click for Details

取付け穴
  • ミニシリーズのブレッドボードおよび構成部品に対応
  • 高さ調整範囲:26.2 mm
  • 取付け面積:76.2 mm x 101.6 mm
  • 垂直方向耐荷重:22.7 kg
  • 取付け穴: M6(7か所)、M4(4か所)、M3(18か所)
  • 1/8インチ(3.18 mm)六角ソケット付きのスチール製親ネジで高さ調整(1/8インチの六角レンチが付属)

ラボジャッキL200/Mは、L490/Mと同様の優れた剛性を発揮するダブルパンタグラフ設計が採用されていますがパッケージサイズは小型となっております。この調整機構では、22.7 kgまでの荷重を支持しながら垂直方向において滑らかな上下動が可能です。 上面と底面のプレートには、多数のタップ穴とザグリ穴があるので、自由な取付けが可能です。 ユニットの背面から操作できる1/8インチの六角ソケット付きスチール製親ネジによって、高さを調整できます(各ユニットに、1/8インチの六角レンチが1個付属)。

+1 数量 資料 型番 - インチ規格 定価(税抜) 出荷予定日
L200 Support Documentation
L200ラボジャッキ、取付け面積4インチ x 3インチ、高さ調整範囲1.03インチ、耐荷重50 lbs(インチ規格)
¥60,069
3-5 Days
+1 数量 資料 型番 - ミリ規格 定価(税抜) 出荷予定日
L200/M Support Documentation
L200/Mラボジャッキ、取付け面積76.2 mm x 101.6 mm、高さ調整範囲26.2 mm、耐荷重22.7 kg (ミリ規格)
¥60,069
Today

小型ラボジャッキ(取付け面積Ø67.0 mm)

  • 安定性の高いラボジャッキ
  • 垂直方向の調整範囲:25.4 mm
  • 取付け面:Ø67.0 mm
  • 耐荷重:90.7 kg
  • 取付け穴: M6(4か所)、M4(9か所)
  • 全範囲で ±0.13 mmの平行度

LJ750/Mは、コンパクトな垂直移動プラットフォームで、高さは完全引きこみ時に50.5 mmで完全延長時に76.5 mmです。 大きな調整ノブには、10 µm単位の目盛が付いているので、精確な高さ調整ができます。上部プラットフォームには、M6とM4の取付け穴があり、 360°の回転が可能で、位置を固定することができます。 ジャッキには、クランプアーム(左図内のPM4(/M)が付属します。

+1 数量 資料 型番 - インチ規格 定価(税抜) 出荷予定日
LJ750 Support Documentation
LJ750小型ラボジャッキ、取付け面積Ø2.64インチ、高さ調整範囲1インチ、耐荷重200 lbs(インチ規格)
¥47,407
3-5 Days
+1 数量 資料 型番 - ミリ規格 定価(税抜) 出荷予定日
LJ750/M Support Documentation
LJ750/M小型ラボジャッキ、取付け面積Ø67.0 mm、高さ調整範囲25.4 mm、耐荷重90.7 kg(ミリ規格)
¥47,407
Today

クランプアーム

  • プラットフォームマウント用のクランプ
  • ポストの上部にM4ネジ穴、下部にM4ネジ付きスタッド
  • 保持できる光学素子の最大高さ:24.6 mm~41.8 mm
  • 保持できる光学素子の高さを拡大するためのエクステンションポストもご用意
    • PM3SP/M + PM3/M:高さ56.1 mmまでの光学素子を保持
    • PM4SP/M + PM4/M:高さ91.7 mmまでの光学素子を保持

Click to Enlarge

クランプアーム用エクステンションポスト。ミリ規格を示す溝が付いています。

こちらのクランプアームを用いると、キネマティックプラットフォームマウントやV字型クランプに光学素子を固定することができます。PM3/Mは高さ24.6 mmまでの光学素子を保持します。ポストと光学素子固定用のナイロン製先端付き止めネジとの中心間距離は17.5 mmです。PM4/Mは高さ40.9 mmまでの光学素子を保持でき、ポストとナイロン製先端付き止めネジとの中心間距離は29.3 mmです。クランプアームPM3/MならびにPM4/Mに、それぞれエクステンションポストPM3SP/MまたはPM4SP/Mを組み合わせると、保持できる光学素子の高さを拡大することが可能です。これらのエクステンションポストは、クランプアームの部品のポストと同一です。すべてのクランプアームにはM4ネジが付属します。

クランプアームPM5/Mはすべて熱処理済みのステンレススチールから作られているため、温度変動を伴う環境中でも安定した性能を維持し、真空にも対応します。M4タップ穴が1つ以上付いているすべてのプラットフォームマウントにお使いいただけますが、特にPOLARIS-K1M4/Mとのご使用をお勧めしています。PM5/Mは高さ41.8 mmまでの光学素子を保持することが可能で、ポストの中心から光学素子を保持する接触点までの距離は22.8 mmです。

各クランプアームはフレクシャ機構でポストに取り付けられますが、その固定には2 mmのボール(六角)ドライバまたは六角レンチを使用します。クランプアーム上部の止めネジで光学素子を固定する際も、2 mmのボールドライバまたは六角レンチを使用します。ポストにはトルクを加えてポストを締め付けるときに使用する貫通穴も付いています。詳細については上の画面をご覧ください。

+1 数量 資料 型番 - インチ規格 定価(税抜) 出荷予定日
PM3 Support Documentation
PM3小型クランプアーム、調整機能付き、#6-32穴付きポスト(インチ規格)
¥2,588
Today
PM3SP Support Documentation
PM3SPCustomer Inspired! クランプアームPM3用エクステンションポスト、#6-32穴付き(インチ規格)
¥718
3-5 Days
PM4 Support Documentation
PM4大型クランプアーム、調整機能付き、#6-32穴付きポスト(インチ規格)
¥3,166
Today
PM4SP Support Documentation
PM4SPCustomer Inspired! クランプアームPM4用エクステンションポスト、#6-32穴付き(インチ規格)
¥718
3-5 Days
PM5 Support Documentation
PM5ステンレススチール製調整機能付きクランプアーム、#8-32穴付きポスト(インチ規格)
¥7,861
3-5 Days
+1 数量 資料 型番 - ミリ規格 定価(税抜) 出荷予定日
PM3/M Support Documentation
PM3/M小型クランプアーム、調整機能付き、M4穴付きポスト(ミリ規格)
¥2,588
Today
PM3SP/M Support Documentation
PM3SP/MCustomer Inspired!  クランプアームPM3/M用エクステンションポスト、M4穴付き(ミリ規格)
¥718
Today
PM4/M Support Documentation
PM4/M大型クランプアーム、調整機能付き、M4穴付きポスト(ミリ規格)
¥3,166
Today
PM4SP/M Support Documentation
PM4SP/MCustomer Inspired! クランプアームPM4/M用エクステンションポスト、M4穴付き(ミリ規格)
¥718
Today
PM5/M Support Documentation
PM5/Mステンレススチール製調整機能付きクランプアーム、M4穴付きポスト(ミリ規格)
¥7,861
Today
ログイン  |   マイアカウント  |   Contacts  |   Careers  |   個人情報保護方針  |   ホーム  |   FAQ  |   Site Index
Regional Websites:East Coast US | West Coast US | Europe | Asia | China
Copyright © 1999-2020 Thorlabs, Inc.
Sales: +81-3-6915-7701
Tech Supports: +81-3-6915-7701


High Quality Thorlabs Logo 1000px:Save this Image