シングルモードファイバー用FC/APCコネクター
- Screw-In Connectors
- 8° Pre-Angled, Spring-Loaded, Ceramic Ferrules
- Typical 10 dB Improvement in Return Loss
Compared to FC/PC Connectors - 2.0 mm Narrow Keys
30126A3
FC/APC Connector Assembled
with Ø3 mm Tubing (Not Included)
Dust Caps and Strain Relief Boots
for Ø2 mm Tubing Can be
Purchased Separately
Exploded View
of 30126A9
Connector
Housing
Boot for
Ø900 µm Tubing
Please Wait
Fiber Connector Selection Guide | |
---|---|
Single Mode | Multimode |
FC/PC FC/APC ST/PC LC/PC | FC/PC (SS Ferrule) FC/PC (Ceramic Ferrule) FC/APC SMA905 ST/PC |
Bare Ferrules | |
Bare Fiber Terminator |
Stock Patch Cables Available with Connectors Sold on This Page | |
---|---|
Single Mode | Polarization-Maintaining |
FC/APC Hybrid Connectors AR-Coated BS-Coated Mirror-Coated | FC/APC Hybrid Connectors AR-Coated Mirror-Coated |
特長
- 幅2.0 mmナローキー付きFC/APCコネクタ
- 高安定なネジ込み固定タイプ
- 8°の端面角度、バネ式、Ø2.5 mm、セラミック製フェルール
- Ø3.0 mmまたはØ900 µmチューブに対応したストレインリリーフブーツとコネクターキャップが付属
ネジ込み型のFC/APCコネクタは、振動の多い環境や後方反射を抑制する用途に向けた設計がされています。 「APC」は「Angled Physical Contact」の略で、このコネクタにより2本のファイバの端面が直接コンタクトして接続されます。また、ファイバの先端が一定の角度に研磨されているので、端面における反射光がファイバに結合されません。 このFC/APCコネクタは、8°に加工済みのセラミック製フェルールが付いています。端面が適切に研磨された場合の反射減衰量の典型値は60 dBです。各パッケージには、ファイバーコネクタ用キャップとプラスチック製ブーツが付属します。
また、コネクタ同士の接続損失の典型値は0.25dBと低くなっています。 ただし、ほかの種類のコネクタと結合すると大幅な挿入損失につながることもあります。FC/APCコネクタはFC/APCコネクタのみと結合させることを推奨します。 用途によりほかの種類のコネクタに結合させる必要がある場合は、ハイブリッドパッチケーブルのご使用をお勧めいたします。
ファイバ、コネクタ、補強チューブを新たに別々に購入して組み立てる代わりに、こちらのページに掲載しているコネクタ付きの標準的なパッチケーブルをご利用いただくことが可能です。 右の表と「パッチケーブル」タブでは、このコネクタを組込んだパッチケーブル製品の一覧がご覧になれます。
Fiber Type | Patch Cable Type | Connectors | Fiber Wavelength Range |
---|---|---|---|
Single Mode | Standard FC/APC | FC/APC to FC/APC | 320 - 2100 nma |
Hybrid Connectors | FC/PC to FC/APC or FC/PC to SMA905 | 320 - 2100 nma | |
AR-Coated | FC/PC to FC/PC, FC/APC to FC/APC, or FC/PC to FC/APC | 320 - 2100 nma | |
BS-Coated | FC/PC to FC/PC or FC/APC to FC/APC | 1260 - 1620 nm | |
Reflective-Coated | FC/PC or FC/APC | 970 - 1620 nma | |
Polarization-Maintaining Single Mode | Standard FC/APC | FC/APC to FC/APC | 405 - 2000 nmb |
Hybrid Connectors | FC/PC to FC/APC | 405 - 2000 nmb | |
AR-Coated | FC/PC to FC/PC or FC/PC to FC/APC | 620 - 1620 nmb | |
Reflective-Coated | FC/PC or FC/APC | 970 - 1550 nm |
コネクタ付きパッチケーブル(標準品)の一覧
ファイバ、コネクタ、補強チューブを新たに別々に購入して組み立てる代わりに、こちらのページに掲載しているコネクタ付きの標準的なパッチケーブルをご利用いただくことが可能です。 表の通り、パッチケーブル(標準品)はシングルモードファイバ、またはシングルモード偏波保持ファイバでご用意しております。また、当社ではこちらのページで販売しているコネクタを使用したカスタムパッチケーブルもご提供しております。詳しくは当社までお問い合わせください。
Posted Comments: | |
bryden.quirk
 (posted 2017-06-01 13:11:51.13) Hi i,m having some trouble getting reliable connections with these connectors the insertion loss seems to increase significantly if the connector is screwed on too tightly or too loosely
and is only acceptable with vary careful adjustment each time the connector is mated
This seems to happen regardless of whether or not a radius is polished onto the ferrule
I am visually inspecting the end face using an inspection scope and all-so using a Telesto OCT system to inspect for undercutting of the fiber.
Do you have any suggestions ? nbayconich
 (posted 2017-06-14 09:48:21.0) Thank you for contacting Thorlabs. It is possible that the key is misaligned between the connector and key slot. I will contact you directly about your application. mjburek
 (posted 2015-07-30 17:53:06.67) Is it possible to buy the green or white fiber ferrule dust caps which are included with single mode fiber patch cords, instead of the clear plastic dust caps sold in packs of 25? Those which come with the single mode fibers have the molded attachment to the fiber, but these often break after extended us and we'd like to replace them. besembeson
 (posted 2015-09-24 09:34:23.0) Response from Bweh at Thorlabs USA: Yes you can. I will follow-up with you. |
Item # | Style | Bore | Concentricity | Ferrule | Included Boot | Crimp Tool for Ø3.0 mm Tubinga | Operating Temperature |
---|---|---|---|---|---|---|---|
30080K2 | 2.0 mm FC/APC Narrow Key | Ø81 +2/-0 µm | 1 µm | Ø2.5 mm, Ceramic | Ø900 µm | Not Required | -40 - 70 °C |
30126A3 | 2.0 mm FC/APC Narrow Key | Ø126 +1/-0 µm | 1 µm | Ø2.5 mm, Ceramic | Ø3.0 mm | CT042 | -40 - 70 °C |
30126A9 | 2.0 mm FC/APC Narrow Key | Ø126 +1/-0 µm | 1 µm | Ø2.5 mm, Ceramic | Ø900 µm | Not Required | -40 - 70 °C |
- ストレインリリーフブーツとØ2 mmチューブ対応の圧着スリーブ(25個入りパック)
- Ø2.5 mmフェルール対応のダストキャップCAPF(25個入りパック)
- FCコネクタ対応の金属製ネジ付きダストキャップCAPFM(4個入りパック)
ストレインリリーフブーツとダストキャップは、ファイバーコネクタとは別にお求めいただけます。ここで掲載している黒色のストレインリリーフブーツはFC/PCおよびFC/APCコネクタとØ2 mm補強チューブに取り付けることができます(当社の標準コネクタには、Ø2 mmチューブに接続できるブーツが付いていません)。
プラスチック製透明ダストキャップCAPFは、Ø2.5 mmファイバーコネクターフェルールおよびFCコネクタと一緒にお使いいただけます。また、ニッケルめっき真鍮製ネジ付きダストキャップCAPFMはナローキーFCコネクタと一緒にお使いいただけます。ファイバの先端に汚れが付着するとファイバーコネクタに致命的な損傷が生じて、結合損失の増加や出力光に不要なモードが生じる可能性があります。 コネクタ付きファイバの損傷を防ぐため、ご使用の前にクリーニング製品を使用してクリーニングを施し、また、ご使用にならない時にはコネクタ付きファイバ端面の保護のため、ファイバーコネクターキャップをご使用ください。