シングルモードファイバ用FC/APCコネクタ

- Screw-In Connectors
- 8° Pre-Angled, Spring-Loaded, Ceramic Ferrules
- Typical 10 dB Improvement in Return Loss
Compared to FC/PC Connectors - 2.0 mm Narrow Keys
30126A3
FC/APC Connector Assembled
with Ø3 mm Tubing (Not Included)
Additional Strain Relief Boots with Crimp Sleeves and Dust Caps Can Be Purchased Separately
Exploded View
of 30126A9
Connector
Housing
Boot for
Ø900 µm Tubing
CAPFM
190066CP

Please Wait
Fiber Connector Selection Guide | |
---|---|
Single Mode | Multimode |
FC/PC FC/APC ST/PC LC/PC E-2000/PC | FC/PC (SS Ferrule) FC/PC (Ceramic Ferrule) FC/APC SMA905 ST/PC |
Bare Ferrules | |
Bare Fiber Terminator |
Stock Patch Cables Available with Connectors Sold on This Page | |
---|---|
Single Mode | Polarization-Maintaining |
FC/APC Hybrid Connectors AR-Coated BS-Coated Mirror-Coated | FC/APC Hybrid Connectors AR-Coated Mirror-Coated |
特長
- 幅2.0 mmナローキー付きFC/APCコネクタ
- 高安定なネジ込み固定タイプ
- 8°の端面角度、バネ式、Ø2.5 mm、セラミック製フェルール
- Ø3.0 mmまたはØ900 µmチューブに対応したストレインリリーフブーツとコネクターキャップが付属
- FC/APCコネクタ対応Ø2 mmまたはØ3.8 mmチューブ用ストレインリリーフブーツと追加のキャップは別売りでご用意
ネジ込み型のFC/APCコネクタは、振動の多い環境や後方反射を抑制する用途に向けた設計がされています。 「APC」は「Angled Physical Contact」の略で、このコネクタにより2本のファイバの端面が直接コンタクトして接続されます。また、ファイバの先端が一定の角度に研磨されているので、端面における反射光がファイバに結合されません。 このFC/APCコネクタは、8°に加工済みのセラミック製フェルールが付いています。端面が適切に研磨された場合の反射減衰量の典型値は60 dBです。各パッケージには、ファイバーコネクタ用キャップとプラスチック製ブーツが付属します。当社では、Ø2 mmまたはØ3.8 mm補強チューブ対応のストレインリリーフブーツ(25個入りパック)と追加のダストキャップ(プラスチック製は25個入り、金属製は4個入りパック)もご用意しています。
また、コネクタ同士の接続損失の典型値は0.25dBと低くなっています。 ただし、ほかの種類のコネクタと結合すると大幅な挿入損失につながることもあります。FC/APCコネクタはFC/APCコネクタのみと結合させることを推奨します。 用途によりほかの種類のコネクタに結合させる必要がある場合は、ハイブリッドパッチケーブルのご使用をお勧めいたします。
ファイバ、コネクタ、補強チューブを新たに別々に購入して組み立てる代わりに、こちらのページに掲載しているコネクタ付きの標準的なパッチケーブルをご利用いただくことが可能です。 右の表と「パッチケーブル」タブでは、このコネクタを組込んだパッチケーブル製品の一覧がご覧になれます。
Fiber Type | Patch Cable Type | Connectors | Fiber Wavelength Range |
---|---|---|---|
Single Mode | Standard FC/APC | FC/APC to FC/APC | 320 - 2100 nma |
Hybrid Connectors | FC/PC to FC/APC or FC/PC to SMA905 | 320 - 2100 nma | |
AR-Coated | FC/PC to FC/PC, FC/APC to FC/APC, or FC/PC to FC/APC | 320 - 2100 nma | |
BS-Coated | FC/PC to FC/PC or FC/APC to FC/APC | 1260 - 1620 nm | |
Reflective-Coated | FC/PC or FC/APC | 970 - 1620 nma | |
Polarization-Maintaining Single Mode | Standard FC/APC | FC/APC to FC/APC | 405 - 2000 nmb |
Hybrid Connectors | FC/PC to FC/APC | 405 - 2000 nmb | |
AR-Coated | FC/PC to FC/PC or FC/PC to FC/APC | 620 - 1620 nmb | |
Reflective-Coated | FC/PC or FC/APC | 970 - 1550 nm |
コネクタ付きパッチケーブル(標準品)の一覧
ファイバ、コネクタ、補強チューブを新たに別々に購入して組み立てる代わりに、こちらのページに掲載しているコネクタ付きの標準的なパッチケーブルをご利用いただくことが可能です。 表の通り、パッチケーブル(標準品)はシングルモードファイバ、またはシングルモード偏波保持ファイバでご用意しております。また、当社ではこちらのページで販売しているコネクタを使用したカスタムパッチケーブルもご提供しております。詳しくは当社までお問い合わせください。
Posted Comments: | |
bryden.quirk
 (posted 2017-06-01 13:11:51.13) Hi i,m having some trouble getting reliable connections with these connectors the insertion loss seems to increase significantly if the connector is screwed on too tightly or too loosely
and is only acceptable with vary careful adjustment each time the connector is mated
This seems to happen regardless of whether or not a radius is polished onto the ferrule
I am visually inspecting the end face using an inspection scope and all-so using a Telesto OCT system to inspect for undercutting of the fiber.
Do you have any suggestions ? nbayconich
 (posted 2017-06-14 09:48:21.0) Thank you for contacting Thorlabs. It is possible that the key is misaligned between the connector and key slot. I will contact you directly about your application. mjburek
 (posted 2015-07-30 17:53:06.67) Is it possible to buy the green or white fiber ferrule dust caps which are included with single mode fiber patch cords, instead of the clear plastic dust caps sold in packs of 25? Those which come with the single mode fibers have the molded attachment to the fiber, but these often break after extended us and we'd like to replace them. besembeson
 (posted 2015-09-24 09:34:23.0) Response from Bweh at Thorlabs USA: Yes you can. I will follow-up with you. |

Item # | Style | Bore | Concentricity | Ferrule | Included Boot | Crimp Tool for Ø3.0 mm Tubinga | Operating Temperature |
---|---|---|---|---|---|---|---|
30080K2 | 2.0 mm FC/APC Narrow Key | Ø81 +2/-0 µm | 1 µm | Ø2.5 mm, Ceramic | Ø900 µm | Not Required | -40 - 70 °C |
30126A3 | 2.0 mm FC/APC Narrow Key | Ø126 +1/-0 µm | 1 µm | Ø2.5 mm, Ceramic | Ø3.0 mm | CT042 | -40 - 70 °C |
30126A9 | 2.0 mm FC/APC Narrow Key | Ø126 +1/-0 µm | 1 µm | Ø2.5 mm, Ceramic | Ø900 µm | Not Required | -40 - 70 °C |

- ストレインリリーフブーツと圧着スリーブは下記の補強チューブ用にご用意
- Ø2 mm補強チューブ用:型番190066CP
- Ø3.8 mm補強チューブ用:型番FT038CP
- 25個入りパックで販売
当社ではファイバーコネクタとは別売りでお買い求めいただけるストレインリリーフブーツをご用意しています。こちらの黒色ストレインリリーフブーツは圧着スリーブが付属しており、FC/PCとFC/APCコネクタに取り付け可能です。ストレインリリーフブーツ190066CPはØ2 mm補強チューブ、ストレインリリーフブーツFT038CPはØ3.8 mm補強チューブに対応しています(当社の標準品のコネクタには、Ø2 mmまたはØ3.8 mm補強チューブに対応するストレインリリーフブーツは付属しておりません)。

- Ø2.5 mmフェルール用ダストキャップCAPF(25個入り)
- FCコネクタ用金属製ネジ付きダストキャップCAPFM(4個入り)
当社ではファイバーコネクタとは別売りでお買い求めいただけるダストキャップをご用意しています。透明プラスチック製のダストキャップCAPFは、すべてのØ2.5 mmファイバーコネクターフェルールとFCコネクタにご使用可能で、ネジ付きニッケルメッキ真鍮ダストキャップは、ナローキー付きのFCコネクタにご使用いただけます。ファイバの先端に汚れが付着するとファイバーコネクタに恒久的な損傷を与え、結合損失の増大や出力光における不要なモードの発生につながる場合があります。コネクタ付きファイバの損傷を防ぐには、ご使用前に毎回ファイバを適切なファイバ用クリーニング用品でクリーニングし、保管時にはファイバの先端を保護するファイバーコネクタ用のキャップを使うことをお勧めします。