顕微鏡用フィルターキューブ、蛍光フィルター取付け済み


  • Pre-Installed Filters Minimize Handling of Bare Optics
  • Drop-In Compatibility with Select Olympus and Nikon Microscopes
  • Matched Filter Sets Designed for Wavelength Ranges of Common Fluorophores

TLV-U-MF2-CFP

CFP Filter Cube for Olympus AX, BX2, and IX2 Microscopes

TLV-U-FF-GFP2

Alexa Fluor® 488 Filter Cube for Olympus BX3 and IX3 Microscopes

TLV-TE2000-TOM

tdTomato Filter Cube for Nikon TE2000 and Eclipse Ti

Related Items


Please Wait
Quick Links
FluorophoreaExcitation / Emission Wavelength
BFP390 nm / 460 nm
CFP434 nm / 479 nm
Wild Type GFP445 nm / 510 nm
GFP469 nm / 525 nm
FITC475 nm / 530 nm
Alexa Fluor® 488482 nm / 520 nm
YFP497 nm / 535 nm
tdTomato531 nm / 593 nm
TRITC542 nm / 620 nm
Texas Red559 nm / 630 nm
mCherry562 nm / 641 nm
Cyanine (Cy3.5) 565 nm / 620 nm
mCherry578 nm / 641 nm
  • フィルターセットは上記リストの蛍光色素向けに最適化されています。その他の蛍光色素については「蛍光色素」タブをご覧ください。

Click to Enlarge

フィルターキューブには取り付けたフィルタが識別しやすいようラベルが付いています。

特長

  • Nikon製ならびにOlympus製顕微鏡用ドロップイン式フィルターキューブ、蛍光フィルターセット取り付け済み(下表をご覧ください)
  • 一般的な蛍光色素向けに最適化されたフィルタ(右表をご覧ください)
  • フィルタを予め取り付けることにより、光学素子そのものの扱いが最小限で済みます
  • フィルターキューブ本体は耐性の高いアルミニウム製
  • 取り付けたフィルタが分かるマーキング用側面ラベル付き

こちらのページでは蛍光フィルターセットを予め取り付けた当社製の顕微鏡用フィルターキューブをご紹介しています。イメージングフィルターセットは13種類からお選びいただけます。いずれも特定の蛍光色素向けに最適化されています(種類については右の表をご覧ください)。フィルターセットはその他の蛍光色素にもご使用いただけます(詳細については「蛍光色素」タブをご覧ください)。フィルターキューブの筐体は、各フィルターセットにつき4種類ご用意しております。Olympus製およびNikon製蛍光顕微鏡に取り付け可能です(対応する顕微鏡については下表をご覧ください)。

当社ではこちらのページのキューブに取り付け可能なフィルタイメージングフィルターセットをほかにもご用意しております。すでにイメージングフィルターセットをお持ちの場合には、空の顕微鏡用フィルターキューブ筐体もご用意しております。 ご要望により、フィルターキューブに当社のほかのフィルタを予め取り付けることも可能です。詳しくは当社までご連絡ください。

フィルタ設計
当社のフィルタは高性能の光学仕様で、耐久性の高い設計となっています。高精度溶融石英基板上に誘電体多層膜を蒸着して製造されています。この基板は高品質の画像を維持するために研磨されています。このような光学素子では、電子ビーム蒸着法で作られたものよりフィルタ層は高密度になります。高密度フィルタは、水分吸収が少ないので、フィルタの耐久性、安定性そして性能が格段に向上します。各フィルタ層は形成中に厚さをモニタリングしているので、設計仕様で定められた厚さからのズレが最小限に抑えられ、結果としてフィルタの全般的な性能が維持されます。


キューブTLV-U-MF2へのフィルタの取付け方法

顕微鏡用フィルターキューブ
キューブは、ダイクロイックミラーの保持機構にバネ板を使用しており、これにより光学素子への負荷が少なくなるため、イメージングの品質が向上します。また、キューブ本体はアルミニウム製で、光学素子の取付けも簡単に行えます。取り付けたフィルタの情報を記入できるラベルも3箇所に付いています。キューブには型番も刻印されています。フィルタが対応する顕微鏡については下表をご参照ください。

フィルターキューブには予めフィルターセットが取り付けられていますが、フィルタは簡単に交換可能です。励起フィルタ1枚(Ø25 mm、厚さ5 mmまで)、吸収フィルタ1枚(Ø25 mm、厚さ3.5 mmまで)、そしてダイクロイックミラー1枚(25.2 mm x 36.0 mm x 1.1 mmまで)がフィルターキューブに対応します。右の動画の通り、光学素子の取り付け、アライメント、そして交換は簡単です。組立方法の詳細については、下表内のマニュアルをご参照ください。

フィルターキューブターレットに使用する際には、重量のバランスが重要です。電動式フィルターキューブターレットの寿命を維持し、不要な摩耗を防止するため、フィルターキューブを反対側にも設置してバランスを保ってください。

Microscope Compatibility of Filter Cubesa
Item # Prefix (Empty Cube Item #)Microscope ManufacturerCompatible MicroscopesAssembly Manual
TLV-U-MF2OlympusAX, BX2, and IX2 SeriesTLV-U-MF2 Manual
TLV-U-FFOlympusBX3 and IX3 SeriesTLV-U-FF Manual
TLV-TE2000NikonTE2000, 50i, 55i, 80i, 90i, Eclipse Ti, and Epi-Fluor Illuminator ScopesTLV-TE2000 Manual
  • 当社では、こちらのページに掲載の無い顕微鏡との互換性は、業界標準タイプの顕微鏡であっても保証しておりませんのでご注意ください。
SpecificationExcitation FiltersEmission FiltersDichroic Filters
MDF-GFP2,
MDF-TOM, MDF-MCHC,
& MDF-MCHA Sets
All Other
Excitation Filters
MDF-GFP2,
MDF-TOM, MDF-MCHC,
& MDF-MCHA Sets
All Other
Excitation Filters
Dichroics in
MDF-GFP2, MDF-MCHA, MDF-MCHC,
& MDF-TOM Sets
All Other Dichroics
SizeØ25 +0.0/-0.1 mmØ25 ± 0.1 mmØ25 +0.0/-0.1 mmØ25 ± 0.1 mm25.2 mm x 35.6 mm25.0 mm x 36.0 mm
Clear Aperture>Ø21 mm>Ø22 mm>Ø21 mm80% of Area>(22.5 mm x 32.4 mm)
Angle of Incidence0° ± 5°45° ± 1.5°
Thickness5.0 ± 0.1 mm3.5 ± 0.1 mm1.05 ± 0.05 mm1.0 ± 0.1 mm
Surface Quality60-40 Scratch-Dig
SubstrateFused Silica
Filter Set Item #FluorophoreFilter TypeCenter WavelengthFWHMReflection BandTransmission BandAR CoatingaTransmission Datab
MDF-BFPBFPExcitation390 nm18 nm---info
Emission460 nm60 nm---
Dichroic--360 - 407 nm425 - 575 nmRabs < 2%
from 400 to 800 nm
MDF-CFPCFPExcitation434 nm17 nm---info
Emission479 nm40 nm---
Dichroic--423 - 445 nm460 - 610 nmRabs < 2%
from 400 to 800 nm
MDF-WGFPWild Type GFPExcitation445 nm45 nm---info
Emission510 nm42 nm---
Dichroic--415 - 470 nm490 - 720 nmRabs < 2%
from 400 to 800 nm
MDF-GFPGFPExcitation469 nm35 nm---info
Emission525 nm39 nm---
Dichroic--452 - 490 nm505 - 800 nmRabs < 2%
from 400 to 800 nm
MDF-FITCFITC
Excitation475 nm35 nm---info
Emission530 nm43 nm---
Dichroic--470 - 490 nm508 - 675 nmRabs < 2%
from 400 to 800 nm
MDF-GFP2GFP
Alexa Fluor® 488
Excitation482 nm18 nm---info
Emission520 nm28 nm---
Dichroic--350 - 488 nm502 - 950 nm-
MDF-YFPYFP
Excitation497 nm16 nm---info
Emission535 nm22 nm---
Dichroic--490 - 510 nm520 - 700 nm-
MDF-TOMtdTomatoExcitation531 nm40 nm---info
Emission593 nm40 nm---
Dichroic--350 - 555 nm569 - 950 nm-
MDF-TRITCTRITCExcitation542 nm20 nm---info
Emission620 nm52 nm---
Dichroic--525 - 556 nm580 - 650 nmRabs < 2%
from 400 to 800 nm
MDF-TXREDTexas RedExcitation559 nm34 nm---info
Emission630 nm69 nm---
Dichroic--533 - 580 nm595 - 800 nmRabs < 2%
from 400 to 800 nm
MDF-MCHCmCherryExcitation562 nm40 nm---info
Emission641 nm75 nm---
Dichroic--350 - 585 nm601 - 950 nm-
MDF-CY3.5Cyanine (CY3.5)Excitation565 nm24 nm---info
Emission620 nm52 nm---
Dichroic--533 - 580 nm595 - 800 nmRabs < 2%
from 400 to 800 nm
MDF-MCHAmCherry
Excitation578 nm21 nm---info
Emission641 nm75 nm---
Dichroic--350 - 588 nm603 - 950 nm-
  • 一部のダイクロイックフィルタは裏面に入射角(AOI)45°用のARコーティングが施されています。
  • Emission Filter をクリックするとプロット図やダウンロード可能なデータをご覧いただけます。
Click to Enlarge
蛍光顕微鏡を通る光の図.

Excitation filter, Emission filter, and dichroic mirror transmission plots
Click to Enlarge

フィルターセットMDF-YFPの透過率グラフ。ダイクロイックミラー(緑色)は励起波長域(青色)内の光を反射し、蛍光波長域(赤色)の光を透過します。

蛍光顕微鏡用フィルタ

蛍光色素
蛍光色素は蛍光を生み出す分子または分子の一部です。分子が基底状態から励起状態まで移るのに必要な周波数の光を受けることで、励起が生じます。しかし、分子はいったん励起状態になると不安定になります。短い時間(通常10-15~10-9秒)の後、光子(フォトン)はリリースされ、分子は低い励起状態に戻ります。振動や音、熱エネルギのような多様なメカニズムによるエネルギの損失を通じて、放射光は吸収光より長い波長(低いエネルギ)になります。 

単体の蛍光色素分子はフォトブリーチングによる破壊(光励起のケミカルダメージや共有結合修飾による不可逆破壊)がなければ、連続して励起することが可能です。フォトブリーチングの前に特定の蛍光色素が受ける励起および発光サイクルの平均的な数は、蛍光色素の分子構造と局所的環境により変わります。数個の光子を放出した直後にフォトブリーチングする蛍光色素分子もあれば、ずっと強固でブリーチする前に何千あるいは何億ものサイクルを経験する蛍光色素分子もあります。

蛍光顕微鏡用フィルタ
右の実験セットアップは、励起光と蛍光の両方が顕微鏡対物レンズを通過する落射蛍光顕微鏡で使われている一般的なフィルタを示しています。用途に合わせて適切なフィルタとミラーを慎重に選ぶことによって、信号対雑音比は最大化されます。右図のように、不要な放射を最小に抑えながら蛍光信号を最大にするために3種類のフィルタが使われています。各光学素子の解説は、下に掲載されています。

励起フィルタ
励起フィルタは、蛍光色素の励起のピーク波長近傍の狭い波長範囲しか透過しません。例えば右のグラフのように、YFP励起フィルタ(MF497-16)の90%を超える透過率に対応するバンドパス領域は489~505 nmです。この範囲外の入射は一部(透過領域に近い領域で)または全部(バンドパス領域から離れた領域で)がフィルタによって阻止されます。

ダイクロイックミラー
ダイクロイックミラーは、特定の波長(カットオフ波長)よりも短い波長の光を反射しますが、それ以外の波長はすべてそのまま通過するよう設計されています。顕微鏡では、ダイクロイックミラーによって適切な波長が試料および像面に向けられます。 各ミラーに対応したカットオフ波長の値は透過の50%に対応する波長を示しています。例えば、右図に示されているように、YFPダイクロイックミラー(MD515)のカットオフ波長は約515 nmとなります。 「仕様」タブには90%以上の平均反射率に対応する 波長範囲と各種のダイクロイックミラーに関する情報が掲載されています。

ダイクロイックミラー1枚を実験セットアップで入射に対して45°に配置することにより、励起光(上図内に青色で表示)はダイクロイックミラーの表面から反射され、試料と顕微鏡対物レンズへと向かいます。一方、試料から発する蛍光(上図内に赤色で表示)はミラーを透過して検出システムへと向かいます。

ダイクロイックミラーは蛍光顕微鏡で重要な役割を果たしますが、不要な光を遮断することとなると完璧とは言えません。一般に、ダイクロイックミラーにより、カットオフ波長より短い波長の光の約90%は反射され、これより長い波長の光の約90%は透過されます。そのため、試料によって放射される(励起光より)長波長の蛍光と一緒に、励起光の一部もダイクロイックミラーを透過してしまいます。 この不要な光が検出システムに届くのを防ぐために、ダイクロイックフィルタのほかに吸収フィルタが使われます。

吸収フィルタ
吸収フィルタは不要な励起光を遮断しながら試料からの蛍光をディテクタに届ける役割を果たします。励起フィルタ同様に、このフィルタは蛍光色素の発光のピーク波長近傍の狭い帯域幅しか透過しません。例えば、右のグラフのように、YFP吸収フィルタ(MF535-22)の90%を超える透過率に対応するバンドパス領域は524~546 nmです。この範囲外の入射は一部(透過領域に近い領域で)または全部(バンドパス領域から離れた領域で)がフィルタによって阻止されます。

Keya
Acceptable - Actual performance depends on individual experimental conditions.
Compatible - Ideal, or nearly ideal, performance under most experimental conditions.
Optimized - Optimal performance under all experimental conditions.

a. が赤色で示されている場合、吸収または発光スペクトルを得ることはできません。

下の表は、当社のフィルターセットが対応可能な全ての蛍光色素です。最上段横列にはフィルターセットの型番、最左縦列には蛍光色素分子が記載されています。スクロールすると当社のフィルターセットと蛍光色素分子の対応がご覧いただけます。

をクリックするとフィルターセットの透過率と蛍光色素分子の吸収ならびに発光スペクトルがご覧になれます。右では下表で使用されているすべてのの定義がご覧いただけます。なお、が赤色で示されている場合、吸収または発光スペクトルを得ることはできません。

 
Fluorophore
(Peak Excitation λ,
Peak Emission λ)
Filter Set Item # Suffix
-BFP-CFP-WGFP-GFP-FITC-GFP2-YFP-TOM-TRITC-TXRED-MCHC-CY3.5-MCHA
1,8-ANS
(372 nm, 477 nm)
2-dodecylresorufin-lipid
(582 nm, 595 nm)
✓✓✓✓
5-carboxy-2,7-dichlorofluorescein
(500 nm, 525 nm)
✓✓
5-carboxynapthofluorescein (pH 10)
(555 nm, 615 nm)
5-FAM (5-carboxyfluorescein)
(492 nm, 518 nm)
✓✓✓✓✓✓
5-ROX (carboxy-X-rhodamine)
(578 nm, 604 nm)
✓✓✓✓✓✓✓
5-TAMRA (5-carboxytetra-
methylrhodamine, pH 7.0)
(542 nm, 568 nm)
6-carboxyrhodamine 6G
(525 nm, 555 nm)
6-JOE
(520 nm, 548 nm)
7-AAD
(548 nm, 648 nm)
Acridine Orange
(502 nm, 526 nm)
Acridine Yellow
(470 nm , 550 nm)
✓✓
Alexa Fluor 350™
(343 nm, 441 nm)
✓✓
Alexa Fluor 405™
(401 nm, 422 nm)
Alexa Fluor 430™
(431 nm , 541 nm)
Alexa Fluor 488™
(499 nm, 520 nm)
✓✓✓✓✓
Alexa Fluor 500™
(503 nm, 525 nm)
✓✓
Alexa Fluor 514™
(518 nm, 543 nm)
Alexa Fluor 546™
(556 nm, 572 nm)
✓✓✓
Alexa Fluor 568™
(579 nm, 603 nm)
✓✓✓✓✓✓✓
Alexa Fluor 594™
(590 nm, 618 nm)
AMCA (Aminomethylcoumarin)
(350 nm, 488 nm)
✓✓
AmCyan1
(458 nm, 489 nm)
✓✓✓✓✓
Amplex UltraRed peroxidation product
-pH 7.5
(568 nm, 581 nm)
Aqua 431
(430 nm,478 nm)
✓✓
AsRed 2
(576 nm, 592 nm)
ATTO 390
(392 nm, 477 nm)
✓✓
ATTO 425
(436 nm, 484 nm)
✓✓✓✓
ATTO 465
(453 nm, 507 nm)
✓✓✓✓✓✓
ATTO 488
(500 nm, 525 nm)
✓✓
ATTO 495
(495 nm, 527 nm)
✓✓✓✓
ATTO 520
(516 nm, 538 nm)
ATTO 550
(553 nm, 576 nm)
ATTO 565
(563 nm, 592 nm)
✓✓✓✓
ATTO 590
(594 nm, 624 nm)
ATTO 594
(601 nm, 624 nm)
BCECF (pH 5.5)
(481 nm, 518 nm)
✓✓✓✓
BCECF (pH 9.0)
(502 nm, 528 nm)
✓✓
BD Horizon V450
(406 nm, 449 nm)
✓✓
BD Horizon V500
(410 nm, 500 nm)
BFP (EBFP)
(380 nm, 440 nm)
✓✓
BOBO™-1
(461 nm, 484 nm)
✓✓✓✓✓
BOBO™-3
(570 nm, 605 nm)
✓✓✓✓
BODIPY FL
(505 nm, 512 nm)
BODIPY FL-MeOH
(502 nm, 511 nm)
BODIPY R6G
(528 nm, 547 nm)
BODIPY TR-X phallacidin
(590 nm, 621 nm)
Calcein
(494 nm, 514 nm)
✓✓
Calcium Crimson
(589 nm, 609 nm)
Calcium Green-1
(507 nm, 529 nm)
✓✓✓
Calcium Orange
(589 nm, 609 nm)
Carboxynaphthofluorescein
(599 nm, 674 nm)
Cascade Blue™
(401 nm, 419 nm)
CellTrace BODIPY TR methyl ester
(598 nm, 625 nm)
CellTrace calcein violet
(400 nm, 452 nm)
✓✓
CellTracker Red CMTPX
(586 nm, 614 nm)
CellTracker Violet BMQC+GSH
(406 nm, 526 nm)
Cerulean
(434 nm, 473 nm)
✓✓✓
CFP (ECFP)
(433 nm, 475 nm)
✓✓✓
CFP2
(490 nm, 510 nm)
✓✓✓✓
Cy2™
(492 nm, 507 nm)
✓✓✓

✓✓

Cy3.5™
(578 nm, 591 nm)
✓✓✓✓✓✓✓
CyQUANT GR-DNA
(502 nm, 523 nm)
✓✓
DAF-FM-NO
(495 nm, 519 nm)
✓✓✓✓
DAPI
(359 nm, 461 nm)
✓✓✓
DDAO
(648 nm, 657 nm)
DEAC
(432 nm, 472 nm)
✓✓
Dendra2 (Green)
(491 nm, 507 nm)
✓✓✓✓
DiA
(457 nm, 586 nm)
DiA
(457 nm, 586 nm)
DiO
(475 nm, 500 nm)
✓✓✓✓✓
Dronpa
(502 nm, 516 nm)
DsRed
(559 nm, 583 nm)
DsRed-Express
(556 nm, 584 nm)
dTomato
(586 nm, 582 nm)
✓✓✓
DY-415
(418 nm, 470 nm)
DY-505-Phalloidin
(503 nm, 530 nm)
✓✓
DY-590
(582 nm, 599 nm)
✓✓✓✓
DyLight 405
(398 nm, 420 nm)
✓✓
DyLight 594
(593 nm, 618 nm)
ECFP
(435 nm, 475 nm)
✓✓
ecliptic pHluorin pH 5.5
(473 nm, 507 nm)
✓✓✓✓✓✓
Emerald
(491 nm, 511 nm)
✓✓✓✓
Eosin
(525 nm, 546 nm)
✓✓✓✓✓
ER-Tracker™ Blue-White DPX
(372 nm, 557 nm)
Ethidium bromide
(518 nm, 603 nm)
Ethidium homodimer
(527 nm, 617 nm)
✓✓
evoglow-Bs1
(449 nm, 496 nm)
✓✓
FITC (Fluorescein)
(495 nm, 519 nm)
✓✓✓✓✓✓✓
FlAsH-CCPFCC
(511 nm, 530 nm)
✓✓
Fluo-3
(506 nm, 527 nm)
✓✓✓
Fluo-4
(494 nm, 516 nm)
✓✓✓✓✓
Fluorescein dextran
(501 nm, 524 nm)
✓✓
Fluorescein-pH 8.0
(489 nm, 517 nm)
✓✓
Fluoro-Emerald
(494 nm, 518 nm)
✓✓
FluoSpheres Crimson fluorescent
microspheres
(620 nm, 646 nm)
FluoSpheres Red fluorescent
microspheres
656 nm, 683 nm)
✓✓✓✓
FluoSpheres Yellow-Green
fluorescent microspheres
(503 nm, 514 nm)
FM 1-43
(473 nm, 579 nm)
GFP (EGFP)
(489 nm, 511 nm)
✓✓✓✓
Green 496
(496 nm, 520 nm)
✓✓✓✓
Green 500
(501 nm, 524 nm)
✓✓
HcRed1
(588 nm, 618 nm)
HCS LipidTOX Green neutral lipid stain
(498 nm, 507 nm)
✓✓
HCS LipidTOX Green phospholipidosis
(504 nm, 536 nm)
✓✓
HCS LipidTOX Red neutral lipid stain
(582 nm, 616 nm)
✓✓✓✓
HCS LipidTOX Red phospholipidosis
(584 nm, 608 nm)
HiLyte Fluor™ 405
(403 nm, 428 nm)
✓✓
HiLyte Fluor™ 488
(497 nm, 526 nm)
✓✓✓✓
HiLyte Fluor™ 594
(592 nm, 616 nm)
Hoechst 33258
(532 nm, 455 nm)
✓✓
Hoechst 33342
(352 nm, 455 nm)
✓✓
Hoechst 34580
(392 nm, 440 nm)
✓✓
Hypericin
(600 nm, 603 nm)
KFP-Red
(575 nm, 599 nm)
✓✓✓✓
LIVE-DEAD Fixable Green Dead Cell Stain
(498 nm, 525 nm)
✓✓✓✓
LIVE-DEAD Fixable Red Dead Cell Stain
(595 nm, 613 nm)
Live-Dead Fixable Violet Dead Cell Stain
(403 nm, 455 nm)
✓✓
LOLO-1
(568 nm, 580 nm)
Lucifer yellow
(428 nm, 544 nm)
LysoSensor Blue
(374 nm, 424 nm)
✓✓
LysoSensor Green
(448 nm, 502 nm)
✓✓✓✓
LysoTracker Green
(501 nm, 509 nm)
LysoTracker Red
(573 nm, 592 nm)
✓✓✓✓
LysoTracker Yellow HCK-123
(488 nm, 565 nm)
Magnesium Green
(507 nm, 531 nm)
✓✓
Magnesium Orange
(587 nm, 610 nm)
mApple
(566 nm, 594 nm)
✓✓✓✓
Marina Blue
(363 nm, 461 nm)
mBBr+GSH
(394 nm, 490 nm)
✓✓
mCherry
(587 nm, 610 nm)
✓✓✓✓✓✓✓✓✓
Mecrocyanine 540
(559 nm, 579 nm)
mHoneyDew
(478 nm, 562 nm)
✓✓
MitoTracker™ Green
(490 nm, 512 nm)
✓✓✓✓
MitoTracker™ Orange
(551 nm, 575 nm)
MitoTracker™ Red
(578 nm, 598 nm)
✓✓✓✓
mKate2
(588 nm, 633 nm)
mPlum
(589 nm,649 nm)
mRFP
(555 nm, 583 nm)
mRFP1
(584 nm, 700 nm)
✓✓✓✓✓
mRuby
(558 nm, 605 nm)
✓✓✓✓✓✓
mStrawberry
(574 nm, 596 nm)
✓✓✓✓✓
mTangerine
(568 nm, 585 nm)
mTFP1
(462 nm, 492 nm)
✓✓
mWasabi
(493 nm, 509 nm)
✓✓
NBD-X (MeOH)
(467 nm, 538 nm)
✓✓✓✓
NeuroTrace 500/525 Green Fluorescence
Nissl Stain
(495 nm, 524 nm)
✓✓✓✓
Nile red-phospholipid
(553 nm, 637 nm)
✓✓✓✓✓✓
Nile red-triglyceride
(510 nm, 583 nm)
OFP
(547 nm, 567 nm)
Orange 552
(552 nm, 574 nm)
Oregon Green™ 488
(488 nm, 526 nm)
✓✓✓✓
Oregon Green™ 514
(513 nm, 532 nm)
Pacific Blue™
(404 nm, 455 nm)
✓✓
PerCP
(490 nm, 677 nm)
pHrodo™, succinimidyl ester
(560 nm, 587 nm)
PicoGreen
(502 nm, 522 nm)
✓✓
PKH67
(488 nm, 500 nm)
✓✓
POPO-1
(433 nm, 457 nm)
✓✓
PO-PRO-1
(433 nm, 456 nm)
✓✓
Propidium Iodide (PI)
(305 nm, 617 nm)
✓✓✓✓
Pro-Q Diamond
(556 nm, 583 nm)
Qdot® 525 Nanocrystals
(300 nm, 525 nm)
Qdot® 545 Nanocrystals
(300 nm, 543 nm)
Qdot® 585 Nanocrystals
(300 nm, 588 nm)
✓✓
Qdot® 605 Nanocrystals
(300 nm, 602 nm)
Qdot® 625 Nanocrystals
(300 nm, 621 nm)
Qdot® 655 Nanocrystals
(300 nm, 654 nm)
ratiometric pHluorin pH5
(500 nm, 509 nm)
ReAsH-CCPGCC
(592 nm, 606 nm)
Red 580
(580 nm, 603 nm)
✓✓✓✓
Resorufin
(571 nm, 584 nm)
Rhod-2
(553 nm, 577 nm)
Rhodamine 110
(497 nm, 519 nm)
✓✓✓✓
Rhodamine 123
(507 nm, 529 nm)
✓✓✓
Rhodamine Green
(497 nm, 523 nm)
✓✓
Rhodamine phalloidin
(558 nm, 575 nm)
Rhodamine Red-X
(573 nm, 951 nm)
✓✓✓✓
Rhodol Green
(497 nm, 524 nm)
✓✓✓✓
rsGFP (red shifted GFP, S65T)
(498 nm, 516 nm)
✓✓
sgBFP™
(387 nm, 451 nm)
✓✓
sgGFP™ (super glow GFP)
(472 nm, 506 nm)
✓✓✓✓✓✓
Sirius
(355 nm, 424 nm)
SNARF (carboxy) 514 Excitation pH 9
(576 nm, 638 nm)
✓✓✓✓
SNARF-1 488 nm (pH 6.0 )
(548 nm, 586 nm)
SNARF-1 488 nm (pH 9.0)
(576 nm, 638 nm)
✓✓✓✓
SNARF-1 514 nm (pH 6.0 )
(549 nm, 587 nm)
✓✓✓✓
SNARF-1 514 nm (pH 9.0)
(576 nm, 638 nm)
✓✓✓✓
Sodium Green
(507 nm, 532 nm)
✓✓
SpectrumAqua
(434 nm, 481 nm)
✓✓
SpectrumBlue
(405 nm, 449 nm)
✓✓
SpectrumGreen
(497 nm, 538 nm)
✓✓
SpectrumOrange
(554 nm, 587 nm)
SpectrumRed
(587 nm, 615 nm)
Sulforhodamine 101-EtOH
(578 nm, 593 nm)
✓✓✓✓
SYBR Gold nucleic acid gel stain-DNA
(469 nm, 539 nm)
✓✓✓✓
SYBR Green I nucleic acid gel stain-DNA
(498 nm, 522 nm)
✓✓✓✓
SYBR Safe DNA gel stain-DNA
(509 nm, 526 nm)
✓✓
SYTO 9
(483 nm, 500 nm)
✓✓✓✓
SYTO 11
(506 nm, 525 nm)
✓✓
SYTO 13
(448 nm, 506 nm)
✓✓✓✓
SYTO 16
(489 nm, 520 nm)
✓✓✓✓✓✓
SYTO 45
(451 nm, 485 nm)
✓✓
SYTO RNASelect green fluorescent
cell stain
(503 nm, 527 nm)
✓✓
SYTOX Blue
(444 nm, 470 nm)
✓✓✓
SYTOX Green-DNA
(504 nm, 524 nm)
✓✓
TagBFP
(402 nm, 457 nm)
✓✓
TagCFP
(458 nm, 480 nm)
✓✓
tdTomato
(556 nm, 582 nm)
✓✓✓
Tetramethylrhodamine dextran
(554 nm, 582 nm)
Texas Red dextran
(592 nm, 613 nm)
Texas Red DHPE
(584 nm, 608 nm)
Texas Red®
(592 nm, 614 nm)
✓✓✓✓✓
ThiolTracker Violet GSH
(404 nm, 526 nm)
TO-PRO-1
(515 nm, 531 nm)
TOTO-1
(514 nm, 531 nm)
TRITC (Tertamethylrhodamine)
(552 nm, 578 nm)
TRITC (Tertamethylrhodamine)
- "reddish"
(552 nm, 578 nm)
✓✓
TurboFP635 (Katushka)
(591 nm, 638 nm)
TurboGFP
(482 nm, 503 nm)
✓✓✓✓
TurboRFP
(553 nm, 573 nm)
TurboYFP
(525 nm, 538 nm)
Venus
(516 nm, 528 nm)
Vybrant DyeCycle Green
(506 nm, 534 nm)
✓✓
Vybrant DyeCycle Orange
(519 nm, 563 nm)
Vybrant DyeCycle Violet
(369 nm, 437 nm)
wtGFP (wild type GFP,
non-UV excitation)
(474 nm, 509 nm)
✓✓✓✓✓✓✓
X-Rhod-1 Indicator
(580 nm, 601 nm)
✓✓✓✓✓✓✓✓
YFP (yellow GFP)
(513 nm, 530 nm)
✓✓✓✓✓
YO-PRO-1
(491 nm, 506 nm)
✓✓✓✓
YOYO-1
(491 nm, 508 nm)
✓✓✓✓
YOYO-3
(611 nm, 631 nm)

Posted Comments:
宇佐川 元久  (posted 2024-02-08 09:30:56.487)
GaN(365nm)の蛍光観察を行いたいと考えており、 365nm以下の波長で励起⇒365nmの波長を観察できる フィルターキューブを検討しております。 ご対応可能でしょうか?
cdolbashian  (posted 2024-02-19 11:04:48.0)
Thank you for reaching out to us with the following inquiry: "I would like to perform fluorescence observation of GaN (365nm). Excitation at a wavelength of 365nm or less ⇒ 365nm wavelength can be observed. I'm considering a filter cube. Is that possible?" Unfortunately, we do not have dichroic mirrors and filters which can be used at this wavelength.
Back to Top

マウント付きBFP用フィルターキューブ(励起波長: 390 nm、蛍光波長: 460 nm)

Item # Suffix-BFP
Design FluorophoreBlue Fluorescent Protein (BFP)
Excitation Band390 ± 9 nm
Emission Band460 ± 30 nm
Dichroic Band (R/T)360 - 407 nm / 425 - 575 nm
Transmission Dataainfo
Filter Set Item #MDF-BFP
  • 他のプロット図やダウンロード可能なデータについてはMore Info Icon をクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-BFP Support Documentation
TLV-U-MF2-BFPCustomer Inspired! Microscopy Cube with Pre-Installed BFP Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-BFP Support Documentation
TLV-U-FF-BFPCustomer Inspired! Microscopy Cube with Pre-Installed BFP Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-BFP Support Documentation
TLV-TE2000-BFPCustomer Inspired! Microscopy Cube with Pre-Installed BFP Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きCFP用フィルターキューブ(励起波長: 434 nm、蛍光波長: 479 nm)

Item # Suffix-CFP
Design FluorophoreCyan Fluorescent Protein (CFP)
Excitation Band434 ± 8.5 nm
Emission Band479 ± 20 nm
Dichroic Band (R/T)423 - 445 nm / 460 - 610 nm
Transmission Dataainfo
Filter Set Item #MDF-CFP
  • 他のプロット図やダウンロード可能なデータについては More Info Icon をクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-CFP Support Documentation
TLV-U-MF2-CFPCustomer Inspired! Microscopy Cube with Pre-Installed CFP Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-CFP Support Documentation
TLV-U-FF-CFPCustomer Inspired! Microscopy Cube with Pre-Installed CFP Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-CFP Support Documentation
TLV-TE2000-CFPCustomer Inspired! Microscopy Cube with Pre-Installed CFP Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きWGFP用フィルターキューブ(励起波長: 445 nm、蛍光波長: 510 nm)

Item # Suffix-WGFP
Design FluorophoreWild Type GFP (WGFP)
Excitation Band445 ± 22.5 nm
Emission Band510 ± 21 nm
Dichroic Band (R/T)415 - 470 nm / 490 - 720 nm
Transmission Dataainfo
Filter Set Item #MDF-WGFP
  • 他のプロット図やダウンロード可能なデータについてはMore Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-WGFP Support Documentation
TLV-U-MF2-WGFPCustomer Inspired! Microscopy Cube with Pre-Installed WGFP Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-WGFP Support Documentation
TLV-U-FF-WGFPCustomer Inspired! Microscopy Cube with Pre-Installed WGFP Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-WGFP Support Documentation
TLV-TE2000-WGFPCustomer Inspired! Microscopy Cube with Pre-Installed WGFP Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きGFP用フィルターキューブ(励起波長: 469 nm、蛍光波長: 525 nm)

Item # Suffix-GFP
Design FluorophoreGreen Fluorescent Protein (GFP)
Excitation Band469 ± 17.5 nm
Emission Band525 ± 19.5 nm
Dichroic Band (R/T)452 - 490 nm / 505 - 800 nm
Transmission Dataainfo
Filter Set Item #MDF-GFP
  • 他のプロット図やダウンロード可能なデータについてはMore Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-GFP Support Documentation
TLV-U-MF2-GFPCustomer Inspired! Microscopy Cube with Pre-Installed GFP Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-GFP Support Documentation
TLV-U-FF-GFPCustomer Inspired! Microscopy Cube with Pre-Installed GFP Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-GFP Support Documentation
TLV-TE2000-GFPCustomer Inspired! Microscopy Cube with Pre-Installed GFP Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きFITC用フィルターキューブ(励起波長: 475 nm、蛍光波長: 530 nm)

Item # Suffix-FITC
Design FluorophoreFluorescein Isothiocyanate (FITC)
Excitation Band475 ± 17.5 nm
Emission Band530 ± 21.5 nm
Dichroic Band470 - 490 nm / 508 - 675 nm
Transmission Dataainfo
Filter Set Item #MDF-FITC
  • 他のプロット図やダウンロード可能なデータについては More Info Icon をクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-FITC Support Documentation
TLV-U-MF2-FITCCustomer Inspired! Microscopy Cube with Pre-Installed FITC Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-FITC Support Documentation
TLV-U-FF-FITCCustomer Inspired! Microscopy Cube with Pre-Installed FITC Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-FITC Support Documentation
TLV-TE2000-FITCCustomer Inspired! Microscopy Cube with Pre-Installed FITC Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きAlexa Fluor® 488用フィルターキューブ(励起波長: 482 nm、蛍光波長: 520 nm)

Item # Suffix-GFP2
Design FluorophoreAlexa Fluor® 488 /
Green Fluorescent Protein (GFP)
Excitation Band482 ± 9 nm
Emission Band520 ± 14 nm
Dichroic Band (R/T)350 - 488 nm / 502 - 950 nm
Transmission Dataainfo
Filter Set Item #MDF-GFP2
  • 他のプロット図やダウンロード可能なデータについてはMore Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-GFP2 Support Documentation
TLV-U-MF2-GFP2Customer Inspired! Microscopy Cube with Pre-Installed Alexa Fluor® 488 Filter Set for Olympus AX, BX2, IX2
¥193,219
Today
TLV-U-FF-GFP2 Support Documentation
TLV-U-FF-GFP2Customer Inspired! Microscopy Cube with Pre-Installed Alexa Fluor® 488 Filter Set for Olympus BX3, IX3
¥193,219
7-10 Days
TLV-TE2000-GFP2 Support Documentation
TLV-TE2000-GFP2Customer Inspired! Microscopy Cube with Pre-Installed Alexa Fluor® 488 Filter Set for Nikon TE2000 and Eclipse Ti
¥186,360
7-10 Days
Back to Top

マウント付きYFP用フィルターキューブ(励起波長: 497 nm、蛍光波長: 535 nm)

Item # Suffix-YFP
Design FluorophoreYellow Fluorescent Protein (YFP)
Excitation Band497 ± 8 nm
Emission Band535 ± 11 nm
Dichroic Band490 - 510 nm / 520 - 700 nm
Filter Set Transmission Dataainfo
Filter Set Item #MDF-YFP
  • 他のプロット図やダウンロード可能なデータについては More Info Icon をクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-YFP Support Documentation
TLV-U-MF2-YFPCustomer Inspired! Microscopy Cube with Pre-Installed YFP Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-YFP Support Documentation
TLV-U-FF-YFPCustomer Inspired! Microscopy Cube with Pre-Installed YFP Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-YFP Support Documentation
TLV-TE2000-YFPCustomer Inspired! Microscopy Cube with Pre-Installed YFP Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きtdTomato用フィルターキューブ(励起波長: 531 nm、蛍光波長: 593 nm)

Item # Suffix-TOM
Design FluorophoretdTomato
Excitation Band531 ± 20 nm
Emission Band593 ± 20 nm
Dichroic Band (R/T)350 - 555 nm / 569 - 950 nm
Transmission Dataainfo
Filter Set Item #MDF-TOM
  • 他のプロット図やダウンロード可能なデータについては More Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-TOM Support Documentation
TLV-U-MF2-TOMCustomer Inspired! Microscopy Cube with Pre-Installed tdTomato Filter Set for Olympus AX, BX2, IX2
¥193,219
7-10 Days
TLV-U-FF-TOM Support Documentation
TLV-U-FF-TOMCustomer Inspired! Microscopy Cube with Pre-Installed tdTomato Filter Set for Olympus BX3, IX3
¥193,219
7-10 Days
TLV-TE2000-TOM Support Documentation
TLV-TE2000-TOMCustomer Inspired! Microscopy Cube with Pre-Installed tdTomato Filter Set for Nikon TE2000 and Eclipse Ti
¥186,360
7-10 Days
Back to Top

マウント付きTRITC用フィルターキューブ(励起波長: 542 nm、蛍光波長: 620 nm)

Item # Suffix-TRITC
Design FluorophoreTetramethylrhodamine Isothiocyanate (TRITC)
Excitation Band542 ± 10 nm
Emission Band620 ± 26 nm
Dichroic Band (R/T)525 - 556 nm / 580 - 650 nm
Transmission Dataainfo
Filter Set Item #MDF-TRITC
  • 他のプロット図やダウンロード可能なデータについてはMore Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-TRITC Support Documentation
TLV-U-MF2-TRITCCustomer Inspired! Microscopy Cube with Pre-Installed TRITC Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-TRITC Support Documentation
TLV-U-FF-TRITCCustomer Inspired! Microscopy Cube with Pre-Installed TRITC Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-TRITC Support Documentation
TLV-TE2000-TRITCCustomer Inspired! Microscopy Cube with Pre-Mounted TRITC Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きTXRED用フィルターキューブ(励起波長: 559 nm、蛍光波長: 630 nm)

Item # Suffix-TXRED
Design FluorophoreTexas Red (TXRED)
Excitation Band559 ± 17 nm
Emission Band630 ± 34.5 nm
Dichroic Band (R/T)533 - 580 nm / 595 - 800 nm
Transmission Dataainfo
Filter Set Item #MDF-TXRED
  • 他のプロット図やダウンロード可能なデータについてはMore Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-TXRED Support Documentation
TLV-U-MF2-TXREDCustomer Inspired! Microscopy Cube with Pre-Installed Texas Red Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-TXRED Support Documentation
TLV-U-FF-TXREDCustomer Inspired! Microscopy Cube with Pre-Installed Texas Red Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-TXRED Support Documentation
TLV-TE2000-TXREDCustomer Inspired! Microscopy Cube with Pre-Installed Texas Red Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きmCherry用フィルターキューブ(励起波長: 562 nm、蛍光波長: 641 nm)

Item # Suffix-MCHC
Design FluorophoremCherry-C
Excitation Band562 ± 20 nm
Emission Band641 ± 37.5 nm
Dichroic Band (R/T)350 - 585 nm / 601 - 950 nm
Transmission Dataainfo
Filter Set Item #MDF-MCHC
  • 他のプロット図やダウンロード可能なデータについてはMore Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-MCHC Support Documentation
TLV-U-MF2-MCHCCustomer Inspired! Microscopy Cube with Pre-Installed MDF-MCHC Filter Set for Olympus AX, BX2, IX2
¥193,219
7-10 Days
TLV-U-FF-MCHC Support Documentation
TLV-U-FF-MCHCCustomer Inspired! Microscopy Cube with Pre-Installed MDF-MCHC Filter Set for Olympus BX3, IX3
¥193,219
7-10 Days
TLV-TE2000-MCHC Support Documentation
TLV-TE2000-MCHCCustomer Inspired! Microscopy Cube with Pre-Installed MDF-MCHC Filter Set for Nikon TE2000 and Eclipse Ti
¥186,360
7-10 Days
Back to Top

マウント付きCyanine用フィルターキューブ(励起波長: 565 nm、蛍光波長: 620 nm)

Item # Suffix-CY3.5
Design FluorophoreCyanine (CY3.5)
Excitation Band565 ± 12 nm
Emission Band620 ± 26 nm
Dichroic Band (R/T)533 - 580 nm / 595 - 800 nm
Transmission Dataainfo
Filter Set Item #MDF-CY3.5
  • 他のプロット図やダウンロード可能なデータについてはMore Info Icon をクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-CY3.5 Support Documentation
TLV-U-MF2-CY3.5Customer Inspired! Microscopy Cube with Pre-Installed Cyanine Filter Set for Olympus AX, BX2, IX2
¥158,757
7-10 Days
TLV-U-FF-CY3.5 Support Documentation
TLV-U-FF-CY3.5Customer Inspired! Microscopy Cube with Pre-Installed Cyanine Filter Set for Olympus BX3, IX3
¥158,757
7-10 Days
TLV-TE2000-CY3.5 Support Documentation
TLV-TE2000-CY3.5Customer Inspired! Microscopy Cube with Pre-Installed Cyanine Filter Set for Nikon TE2000 and Eclipse Ti
¥151,896
7-10 Days
Back to Top

マウント付きmCherry用フィルターキューブ(励起波長: 578 nm、蛍光波長: 641 nm)

Item # Suffix-MCHA
Design FluorophoremCherry-A
Excitation Band578 ± 10.5 nm
Emission Band641 ± 37.5 nm
Dichroic Band (R/T)350 - 588 nm / 603 - 950 nm
Transmission Dataainfo
Filter Set Item #MDF-MCHA
  • 他のプロット図やダウンロード可能なデータについてはMore Info Iconをクリックしてください。
+1 数量 資料 型番 - ユニバーサル規格 定価(税抜) 出荷予定日
TLV-U-MF2-MCHA Support Documentation
TLV-U-MF2-MCHACustomer Inspired! Microscopy Cube with Pre-Installed MDF-MCHA Filter Set for Olympus AX, BX2, IX2
¥193,219
7-10 Days
TLV-U-FF-MCHA Support Documentation
TLV-U-FF-MCHACustomer Inspired! Microscopy Cube with Pre-Installed MDF-MCHA Filter Set for Olympus BX3, IX3
¥193,219
7-10 Days
TLV-TE2000-MCHA Support Documentation
TLV-TE2000-MCHACustomer Inspired! Microscopy Cube with Pre-Installed MDF-MCHA Filter Set for Nikon TE2000 and Eclipse Ti
¥186,360